Rogowski AC Current Probe RCP Series

Printer Friendly Tell a Friend
Rogowski AC Current Probe RCP Series
Price: 

Qty:

Highlights:
  • Bandwidth: 2Hz-30MHz
  • Coil cross-section (diameter): 1.6mm
  • Accuracy (typical): 2%
  • Peak current: 12000Apk
  • Interface: BNC

  Description  

Rogowski AC Current Probe RCP Series

Product Details

Micsig RCP series Rogowski current probe measures AC currents up to 12000Apk, max. bandwidth up to 30MHz, withstand voltage is up to 1kVrms, nearly zero insertion impedance, greatly minimized the interference to the DUT.
A 1.6mm thin, flexible, clip-around Rogowski coil allow user easily pass through pin leg of TO-220 semiconductor devices. With 2% accuracy (typical) , accurately measures high-frequency and high-current signals like double-pulse dynamic test, monitor semiconductor switch current.

Measure the Id current of MOSFET

The RCP has excellent high-frequency measurement capabilities, easily handles high-speed signals and rapidly changing current waveforms, helping to observe high-frequency harmonic components when measuring the Id current of MOSFETs. (as shown the oscillation section).

Smallest coil cross-section

The cross-sectional diameter of the coil is only 1.6mm, allow engineers measure current in most difficult-to-reach parts of the circuit, such as narrow pin spacing chip like TO-220, TO-47.
Most compact flexible design easily solved the hard-to reach part issue, coil diameter support customzied made to meet more test requirements

BNC interface

Standard BNC interface to use on any oscilloscope.

Applications

  • Measuring current in motor drives and in particular power quality measurements in VSD, UPS or SMPS circuits
  • Double-pulse testing to measure the pin currents of MOSFET and IGBT chips made of materials such as SiC and GaN
  • Measurement of load current and high-order harmonic current in power electronics
  • Measuring high frequency sinusoidal, pulsed or transient currents
  • Measuring AC currents in 3-phase supply system
  • Measuring the power consumption in semiconductors
  • Measurement of 50/60Hz power frequency current
  • Power converter development and diagnostics

Key Specifications

ModelRCP60XSRCP120XSRCP300XSRCP600XSRCP1200XSRCP3000XSRCP6000XSRCP12000XS
Bandwidth85Hz - 30MHz 34Hz - 30MHz10Hz - 30MHz10Hz - 30MHz12Hz - 30MHz3Hz - 30MHz2Hz - 30MHz 2Hz - 30MHz
Peak current60Apk120Apk300Apk600Apk1200Apk3000Apk6000Apk 12000Apk
Output sensitivity100mV/A(10x)50mV/A(20x) 20mV/A (50X)10mV/A(100X)5mV/A (200X)2mV/A(500X)1mV/A(1000X) 0.5mV/A(2000X)
Accuracy (typical)2%2% 2%2%2%2%2% 2%
Peak di/dt4kA/μs8kA/μs 20kA/μs40kA/μs70kA/μs70kA/μs70kA/μs 70kA/μs
Droop65%/ms35%/ms 9%/ms6%/ms3%/ms2%/ms2%/ms 2%/ms
Noise<20mVpp <20mVpp<18mVpp<12mVpp<5mVpp<5mVpp<5mVpp <6mVpp
Peak coil isolation voltageAC 1kVrms (1min) (50Hz/60Hz) ( Rogowski coil part only)
Cable length1.5m,from integrator to coil, customizable
Rogowski coil inner diameter25mm, measures wires within 20mm in diameter , customizable
Rogowski coil circumference80mm, customizable
Coil cross-section diameter1.6mm
Output impedance

1MΩ

Interface

Universal BNC